-305 m (1000 ft)/karton UTP CAT5e, napajanje preko Etherneta, kompatibilan sa jednim kablom
-Bakarni provodnik oxygen-free visoke cistoce
-Prilagodeni PVC spoljni omotac; CE CPR Eca sertifikovana klasa otpornosti na vatru
Material: Oxygen free copper (99.97% purity)
Diameter: 0.45 mm ± 0.01 mm
Insulation
Material: HDPE
Min. Average Thickness: 0.18 mm
Diameter: 0.81mm±0.1mm
Color (4 Pairs): Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown
Rip Cord
Material: Polyester
Specification: 500D
Sheath
Material: PVC
Min. Average Thickness: 0.5 mm
Diameter: 4.7 mm ± 0.3 mm
Color: White
Electrical
Max. DC Resistance of a Single Conductor: 12O/100 m
Min. Insulation Resistance: 5000MO·km
Max. DC Resistance Unbalance: 2% (pair intra), 4% (pairs inter)
Dielectric Strength: No breakdown with 1KV DC for 1 min
Transmission
Characteristic Impedance: 100 ± 15O
Near End Cross Talk: =35.30 dB/100 m@100 MHz
Max. Attenuation: 24.2 dB/100 m@100 MHz
Return Loss: =20.1 dB/100 m@100 MHz
Mechanical
Tensile Strength:
Sheath=13.5 MPa, insulation=16 MPa
Elongation at Break: Sheath=150%, insulation=300%
Installation Bending Radius: >8 times of outer cable diameter
Conductor Elongation at Break: =10%
Environmental
Shrinkage of Insulation: =5%
Color Migration Resistance of Insulation: No migration
Sheath Tensile Strength and Elongation at Break after Aging: =12.5 MPa, =100%
Low Temperature Bending Test: No cracking after the test
Heat Shock Test: No cracking after the test
Operating Temperature: –20°C to +60°C (–4°F to 140°F)
Installation Temperature: 0°C to +50°C (32°F to 122°F)
Storage Temperature and Humidity: –10°C to +40°C (14°F to 104°F), <60% (RH)
Security
Vertical Fire Propagation Test: Comply with IEC 60332-1-2
Packaging
Cable Length: 305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)
Inner Carton Dimensions: 364.0 mm × 364.0 mm × 216.0 mm
(14.33″ × 14.33″ × 8.50″) (L × W × H)
Packaging Method: 305.0 m (1000.66 ft) a carton, one master carton with 2 inner cartons
Net Weight: =7.0 kg (15.43 lb)
Gross Weight: =8.0 kg (17.64 lb)
Compliance
Executive Standards: Q/DXJ 067-2019, EN50575-2014
Certification: CPR Eca